Common building defects and the code behind them
Building inspectors see the same defects again and again. Most of them trace back to a handful of NCC provisions, Australian Standards or simple maintenance problems. This page lists the common ones and links to the guide for each, so you can explain the cause in a report, not just the symptom.
Last checked: 13 November 2026. For inspectors, builders and trades. Pre-purchase inspections under AS 4349.1 are condition reports, not compliance audits. Use the code to explain a defect, not to say an older house fails a code it was never built to.
Water
Water is behind more defects than anything else.
| Defect | Usual causes | Guide |
|---|---|---|
| Leaking shower, lifting tiles, damp walls next to bathrooms | Failed or missing membrane, no floor waste, poor falls | Wet area waterproofing |
| Damp at the base of walls, salt, crumbling mortar | Bridged or missing damp-proof course, high ground, blocked weep holes | Rising damp, Brickwork and DPCs |
| Water stains on ceilings | Roof leaks, gutter overflow, box gutters, condensation | Roof leaks, Gutters |
| Water under doors, damp floors after rain | Ground or paving too high, poor site drainage | Site drainage |
| Musty subfloor, rot, mould | Poor subfloor ventilation, damp soil | Subfloor ventilation |
| Leaking balconies and stains below them | Membrane failure, poor falls, threshold details | Decks and balconies |
| Leaks around windows | Missing or reversed flashings | Wall cladding and flashings |
Movement and structure
| Defect | Usual causes | Guide |
|---|---|---|
| Cracks in walls, slabs and plaster; sticking doors | Reactive clay, poor drainage, trees, leaking pipes | Cracking in houses, Site classification |
| Sagging roof lines, missing tie-downs, cut trusses | Overloading, renovations, poor framing | Framing, wind and tie-downs |
| Rotting decks and posts | Non-durable timber, rusted fixings, poor drainage | Decks and balconies |
Safety
| Defect | Usual causes | Guide |
|---|---|---|
| Low or climbable balustrades, wide gaps | Older construction, DIY work | Stairs and balustrades |
| Ordinary glass in doors and low panels | Older construction | Safety glass |
| Missing or old smoke alarms | Older homes, no replacement | Smoke alarms |
| Pool fence gaps, faulty gates | Wear, landscaping, objects in the climbable zone | Pool barriers |
| Very hot water at the shower | No tempering valve | Hot water temperatures |
| Buried or blocked overflow relief gully | Landscaping, paving | Sanitary plumbing |
Unapproved work
Converted garages, enclosed verandahs, granny flats and extensions without approval are common findings. Look for work that doesn't match the age or style of the house, rooms below ceiling height, and missing fire separation near boundaries. See garages and Class 10, ceiling heights, light and ventilation and fire separation.
Older houses
Knowing which rules applied when the house was built helps you explain a finding fairly. See which building code applied when.
Writing it up
- Describe what you saw and measured, and where.
- Say what it is likely to mean, and what further investigation is needed.
- Where you mention the code, name the provision and say it's current guidance, not a statement that the house fails a code it predates.
- Photos next to each finding make a report easier to read and harder to dispute.
This guide is general information, not legal or professional advice.