Site classification, footings and slabs: AS 2870 in plain words
Before a slab is poured, someone has to work out how much the ground under it will move. Clay soils swell when they get wet and shrink when they dry out, and a slab designed for sand will crack on reactive clay. That is what site classification is for, and it drives the footing design for almost every new house.
Last checked: 13 November 2026. This summarises the NCC and the classes in AS 2870; it does not reproduce the Standard. Check the edition and state variations that apply to your job.
Where the rules are
- NCC Volume Two, Part H1, Structure.
- Housing Provisions Section 4, Footings and slabs (Part 4.2).
- AS 2870 Residential slabs and footings, which sets out how a site is classified and how footings are designed for each class.
Housing Provisions Part 4.2 only covers the simpler cases. Where a site is classified M-D (deep-seated moisture change), the Housing Provisions send you straight to AS 2870 for the design.
The site classes
A geotechnical engineer tests the soil and works out the characteristic surface movement (ys): how much the ground surface is expected to move up and down with moisture changes over the life of the house. That sets the class.
| Class | What it means | Typical surface movement |
|---|---|---|
| A | Most sand and rock sites, little or no movement | 0 to 10 mm |
| S | Slightly reactive clay | 10 to 20 mm |
| M | Moderately reactive clay or silt | 20 to 40 mm |
| H1 | Highly reactive clay | 40 to 60 mm |
| H2 | Highly reactive clay | 60 to 75 mm |
| E | Extremely reactive clay | 75 mm or more |
| P | Problem site | Not classified by movement |
A P (problem) site is one that cannot be classified on movement alone: soft or unstable ground, uncontrolled fill, soils subject to erosion, or reactive sites with abnormal moisture conditions. P sites need an engineer's design.
A "-D" after the class (for example M-D or H1-D) means deep-seated moisture change, which is common in drier inland areas.
What the class changes
The class decides how stiff the slab or footing has to be: the depth and spacing of beams, the reinforcement, and extra requirements for reactive sites. On M, H1, H2 and E sites, AS 2870 also adds requirements for:
- Drainage around the house, because water pooling against a slab on clay causes uneven movement.
- Plumbing, with flexible joints where pipes leave the slab.
- Masonry detailing, such as articulation joints in brickwork.
- Trees, because roots dry out clay. Engineers' reports commonly recommend keeping trees back from the house by a set fraction of their mature height, more on more reactive sites.
Owners have a part to play
A slab designed for its class can still crack if the site is badly managed after handover. AS 2870 includes advice for owners on foundation maintenance: keep the ground sloping away from the house, fix leaking pipes and taps, don't let garden beds or sprinklers soak the slab edge, and think before planting trees near the house.
What inspectors should look for
- Cracks in slabs, brickwork and internal plaster, and whether doors and windows stick. See our guide to cracking in houses.
- Ground that slopes towards the house, and ponding against the slab.
- Trees close to the house on clay sites.
- Leaking downpipes, taps or stormwater pipes next to the footings.
Sources
- NCC 2022 Volume Two, Part H1, and ABCB Housing Provisions Part 4.2: ncc.abcb.gov.au
- Monash City Council, soil investigation guidance (AS 2870 classes)
This guide is general information, not legal or engineering advice. AS 2870 is available from Standards Australia.