Sanitary plumbing and drainage: overflow relief gullies, grades and vents
Sanitary plumbing and drainage takes waste from toilets, showers, basins, sinks and laundries to the sewer or an on-site system. When it is laid wrong, it blocks, smells or, in the worst case, sends sewage back up inside the house. The overflow relief gully is the safety valve that stops that.
Last checked: 13 November 2026. Based on the Plumbing Code of Australia and the way AS/NZS 3500.2 is called up. Water utilities and state plumbing regulators set extra rules. Check yours.
Where the rules are
- NCC Volume Three, Part C2, Sanitary plumbing and drainage systems.
- AS/NZS 3500.2 Sanitary plumbing and drainage, the Deemed-to-Satisfy standard.
- Local water utility rules for connections to the sewer, and on-site wastewater rules in unsewered areas.
The overflow relief gully (ORG)
If the sewer blocks downstream, sewage backs up and comes out of the lowest opening it can find. The ORG is designed to be that opening, outside the house.
AS/NZS 3500.2 requires at least one ORG in a drainage system (with limited exemptions), and two heights matter:
- The top of the gully riser must be at least 150 mm below the lowest fixture connected to the drain. The lowest fixture includes a floor waste gully, usually in the bathroom or laundry.
- The top of the gully riser must be at least 75 mm above the surrounding ground, so rain and surface water can't run in. A lower height is allowed in paved areas, provided the paving falls away from the gully.
The grate must be able to lift off freely. A grate that is cemented in, covered by a pot plant or buried under landscaping defeats the whole point.
Where the 150 mm can't be achieved, a reflux valve may be needed as well, but it doesn't remove the need for an ORG.
Grades, sizes and vents
AS/NZS 3500.2 sets:
- Minimum pipe sizes and grades, so waste flows at the right speed: not so flat that solids settle, not so steep that water outruns the solids.
- Fixture unit loadings, which decide pipe sizes from the number and type of fixtures connected.
- Venting, so the system doesn't siphon the water out of traps (which lets sewer gas into the house) and can breathe.
- Inspection openings, so drains can be cleared.
Flood-prone areas
In areas subject to flooding, the inlet to the sanitary system (often the ORG) generally needs to sit above the declared flood level.
Renovations and landscaping
Two common ways an existing ORG stops working:
- New paving, decks or garden beds raise the ground around the gully, or cover it.
- A new bathroom or floor waste is installed lower than the ORG.
See our site drainage guide.
What inspectors should look for
- No visible ORG, or one buried, covered or concreted over
- ORG riser below the surrounding ground, letting surface water in
- Floor wastes inside at a level close to or below the ORG
- Sewer smells inside, slow drains, or gurgling fixtures
- Cracked or root-damaged drains (signs: wet patches, sinkholes, lush grass along the drain line)
Sources
- NSW Government, overflow relief gully requirements advisory note
- QBCC, overflow relief gullies
- Building and Plumbing Commission Victoria, practice note DR-09
- Hunter Water, check your overflow relief gully
This guide is general information, not legal or plumbing advice. AS/NZS 3500.2 is available from Standards Australia.