Wall cladding and flashings under the NCC

Weatherboards, fibre-cement and composite cladding keep rain off the frame, but only if they are fixed, lapped and flashed properly and kept clear of the ground. Leaks around windows and at the base of walls are among the most common defects in lightweight-clad homes.

Last checked: 13 November 2026. Based on NCC 2022 Housing Provisions Part 7.5 and Part H2 of Volume Two. Check the edition, state variations and the manufacturer's instructions for your job.

Where the rules are

  • NCC Volume Two, Part H2, Damp and weatherproofing.
  • Housing Provisions Part 7.5, Timber and composite wall cladding (weatherboards, fibre-cement boards and sheets, plywood).
  • Masonry cladding, including brick veneer, is covered separately in Section 5. See our brickwork guide.
  • Cladding not covered by Part 7.5 must follow the manufacturer's tested system or be assessed as a Performance Solution.

Fixing

Part 7.5 sets fixing details by material, thickness, stud spacing and wind class: the type of nail or screw, spacings in the body and at the edges of sheets, closer spacings near external corners, and minimum distances from sheet edges. The higher the wind class, the closer the fixings. See our framing and wind guide.

Clearance to the ground

Cladding must stay clear of the ground so it does not wick up moisture, rot, or give termites a hidden path. The Housing Provisions set minimum clearances between the bottom of the cladding and the finished ground: a smaller clearance to paved, impermeable surfaces and a larger one to soil. On suspended floors, the cladding must also extend a minimum distance below the bearer so water drips clear of the subfloor framing.

Wall wraps and flashings

  • A pliable membrane (wall wrap) behind the cladding is the second line of defence. It must have the right vapour permeance for the climate zone so the wall can dry out. See our condensation guide.
  • Flashings are needed at window and door heads and sills, at the junction of walls and roofs, at changes of cladding, and around penetrations such as pipes and vents.
  • Windows in houses must comply with AS 2047, which covers how they are installed and flashed into the wall.

NCC 2025

NCC 2025 adds new external water management provisions and changes the condensation rules for external walls. Check which edition applies to your job in our NCC 2025 guide.

What inspectors should look for

  • Cladding in contact with soil, mulch or paving
  • Swollen, cracked or rotting boards, especially at the bottom course and below windows
  • Missing or reversed flashings at window heads, and sealant used instead of flashing
  • Gaps at cladding joints and around penetrations
  • Water stains inside below windows

Sources

  • NCC 2022 Volume Two, Part H2, and ABCB Housing Provisions Part 7.5: ncc.abcb.gov.au
  • NSW Building Commission, flashing guidance

This guide is general information, not legal or compliance advice.