Wet area waterproofing under the NCC

Leaking showers are one of the most common building defects in Australia. The water gets past the tiles, soaks the floor or the wall frame, and the damage shows up months later as lifting tiles, swollen skirting or mould on the other side of the wall.

This guide explains where the NCC rules for wet areas are, what has to be waterproof and what only has to be water resistant, and what installers and inspectors should look for.

Last checked: 13 November 2026. This summarises the NCC; it does not reproduce AS 3740. Check the edition and state variations that apply to your job.

Where the rules are

For houses (Class 1), the rules are in:

  • NCC Volume Two, Part H4, which sets the Performance Requirement (H4P1) and the Deemed-to-Satisfy clause (H4D2); and
  • Housing Provisions Part 10.2, Wet area waterproofing, which has the construction detail.

H4D2 gives two ways to comply with the Deemed-to-Satisfy path:

  1. The Housing Provisions Part 10.2 in full; or
  2. AS 3740 Waterproofing of domestic wet areas, provided the wet area also meets the parts of the Housing Provisions that say which areas need to be waterproof or water resistant.

For apartments and other Class 2 to 9 buildings, Volume One clause F2D2 and Specification 26 set the areas, and AS 3740 applies to domestic wet areas such as the bathrooms in apartments.

Waterproof versus water resistant

The NCC uses two different terms, and they are not the same thing.

  • Waterproof means the material stops water getting through it. Shower floors are the obvious example.
  • Water resistant means the material resists water getting through it under occasional exposure, such as the bathroom floor outside the shower or the wall behind a basin.

Since NCC 2022, every building element in a wet area has to be either waterproof or water resistant. The Housing Provisions set which is needed where.

The shower area

The shower area gets the highest protection. Under the Housing Provisions, the floor of the shower area must be waterproof, along with the junctions where walls meet the floor and the penetrations for taps and outlets. Walls in the shower area must be at least water resistant to a set height.

The shower area also needs a floor waste. Hobs, step-downs, level-entry showers and preformed shower bases each have their own details.

Outside the shower

The rest of the bathroom floor, laundry floors and the floor around a toilet need lower levels of protection, depending on the floor material. Timber and particleboard floors need more than concrete. Since NCC 2022, structural plywood and particleboard flooring are no longer treated as water resistant just by themselves in all areas, so check the material rules.

What installers should check

  • The waterproofing product is compatible with the substrate and the tile adhesive.
  • Membrane thickness and curing follow the manufacturer's instructions.
  • Bond breakers are in at wall and floor junctions where the system needs them.
  • Falls in the floor take water to the waste, with no ponding.
  • The waterproofing is inspected before it is covered. In NSW, this is a critical stage inspection for houses. See our stage inspections guide.

What inspectors should look for

You cannot see a membrane once it is tiled. You can see the signs that it has failed:

  • Drummy or cracked tiles, and grout that keeps cracking in the same line
  • Water staining, swelling or mould on the other side of the shower wall, or on skirting boards and door frames outside the bathroom
  • High moisture readings in walls or floors next to the shower
  • No floor waste, or floors that fall away from the waste
  • Silicone used to hold back water at the edge of the shower

Moisture meter readings and thermal images help, but report what you saw and measured, not what you assume is behind the tiles.

Sources

  • NCC 2022 Volume Two, Part H4, and ABCB Housing Provisions Part 10.2: ncc.abcb.gov.au
  • ABCB, "Waterproofing houses" explainer: nccb.gov.au
  • Building and Plumbing Commission Victoria, waterproofing of wet areas guidance

This guide is general information, not legal or compliance advice. AS 3740 is available from Standards Australia.