Fire safety measures and annual statements (AFSS, ESM, occupier statement)

A building's fire safety systems only work if they're maintained. Every state requires owners of apartments and commercial buildings to keep their fire safety measures working, and most require a yearly statement or report saying so. For fire trades, electricians and strata managers, this is recurring work.

Last checked: 13 November 2026. These rules come from state law, not the NCC. They differ between states and change from time to time. Check yours.

What fire safety measures are

Fire safety measures are the systems and features a building relies on in a fire. They're set by the building's approval and listed on its fire safety schedule or equivalent. Common examples:

  • Fire detection and alarm systems, and smoke alarms
  • Sprinklers and fire hydrants, hose reels and booster assemblies
  • Portable fire extinguishers and fire blankets
  • Emergency lighting and exit signs. See our emergency lighting guide
  • Fire doors, fire-rated walls and penetration seals. See our fire resistance guide
  • Smoke control and mechanical air handling
  • Paths of travel to exits. See our exits guide

New South Wales: annual fire safety statement (AFSS)

  • Owners must maintain the building's essential fire safety measures, under the Environmental Planning and Assessment (Development Certification and Fire Safety) Regulation 2021.
  • An annual fire safety statement must be given to the council and Fire and Rescue NSW each year, and displayed in the building.
  • Each measure must be assessed by an Accredited Practitioner (Fire Safety) within the three months before the statement's date.
  • Critical fire safety measures may need supplementary statements more often than once a year.

Victoria: essential safety measures (ESM)

  • Owners must maintain the essential safety measures listed on the occupancy permit or maintenance determination.
  • An annual essential safety measures report (AESMR) must be prepared, kept on site and made available to the council or fire brigade on request.

Queensland: occupier statement

  • Occupiers must maintain prescribed fire safety installations under the Building Fire Safety Regulation.
  • An occupier statement must be given to Queensland Fire Department each year, confirming the installations have been maintained.

Other states and territories

The other states and territories have their own maintenance and reporting rules. Check the building or fire regulator for yours.

Maintenance standards

Routine servicing is usually done to AS 1851, Routine service of fire protection systems and equipment, which sets the inspection and testing frequencies for each type of system. Some systems need monthly, six-monthly and yearly checks.

Houses

Ordinary houses (Class 1a) don't need annual fire safety statements, but state smoke alarm laws apply, especially for rentals. See our smoke alarms guide.

What inspectors and trades should look for

  • No current AFSS (NSW) or ESM report (Vic) displayed or available
  • Fire doors wedged open, damaged or modified
  • Extinguishers out of date or missing tags
  • Exit signs not lit
  • New penetrations through fire-rated walls with no seal

Sources

  • NSW councils' annual fire safety statement guidance (Hornsby, Sutherland Shire, Penrith)
  • Victorian Building Authority / Building and Plumbing Commission, essential safety measures
  • Wormald, fire safety compliance requirements across Australia

This guide is general information, not legal or fire safety advice.