Exits and egress: getting people out of a building
When there's a fire, people need to get out quickly, even in smoke and in the dark. The NCC's egress rules for apartments and commercial buildings set how many exits a building needs, how far people can travel to reach one, how wide the paths must be, and how exit doors work.
Last checked: 13 November 2026. Based on NCC 2022 Volume One, Section D. States vary some of these rules. Check the edition and state variations that apply to your job.
Where the rules are
- NCC Volume One, Section D, Access and egress.
- Part D2, Provision for escape: number of exits, travel distances, widths.
- Part D3, Construction of exits: stairs, ramps, doors, barriers and handrails in commercial and apartment buildings.
Inside an apartment (a sole-occupancy unit in a Class 2 or 3 building), most of these rules don't apply, because people know their way around their own home.
Number of exits
Every storey needs at least one exit. Two or more are needed in many cases, such as taller buildings, larger floors, and some Class 9 buildings (hospitals, schools, aged care), where people may be slower to evacuate.
Travel distances
Travel distance is measured along the path someone would actually walk.
- Class 5 to 9 buildings (offices, shops, factories, schools): no point on the floor may be more than 20 m from an exit or from a point of choice, where people can go in different directions to two exits. Where there's a point of choice, the distance to one of the exits is limited (generally to 40 m).
- Class 2 and 3 buildings (apartments, hotels): the entrance door of each unit must be no more than 6 m from an exit or a point of choice, or no more than 20 m from a single exit on the level that opens to the street.
Health-care and early childhood buildings have shorter distances in some states.
Widths and heights
Paths of travel to exits must have minimum clear widths and an unobstructed height of at least 2 m. Widths increase with the number of people the floor is designed for.
Fire-isolated stairs
In taller buildings, exit stairs must be fire-isolated: enclosed in fire-rated walls with fire doors, so people can get down safely. See our fire resistance guide.
Exit doors
Exit doors must be easy to open from the inside without a key, usually swing in the direction of travel, and not be obstructed. Locks and access control systems on exit doors must release for egress.
Visibility
Exits must be signed and lit so people can find them in smoke or a power failure. See our emergency lighting and exit signs guide.
What inspectors and trades should look for
- Exit paths blocked by stock, furniture or bins
- Exit doors locked, chained or needing a key from inside
- Fire doors on stairs wedged open
- Paths narrowed by fit-outs and partitions
- Missing or dark exit signs
Sources
- ABCB, Guide to D2D5 exit travel distances: abcb.gov.au
- NCC 2022 Volume One, Section D: ncc.abcb.gov.au
This guide is general information, not legal or compliance advice.