Disability access in buildings: the Premises Standards and the NCC
Most new and upgraded public and commercial buildings must be accessible to people with disability. The rules come from two places that work together: the federal Premises Standards and the NCC's access provisions, which call up AS 1428.1.
Last checked: 13 November 2026. Based on NCC 2022 Volume One. Access rules have exemptions and can involve discrimination law, not just building law. This is a summary only.
Where the rules are
- Disability (Access to Premises — Buildings) Standards 2010 (the "Premises Standards"), made under the federal Disability Discrimination Act 1992.
- NCC Volume One, Part D4, Access for people with a disability, plus related provisions in Parts E3 (lifts) and F4 (accessible sanitary facilities).
- AS 1428.1 Design for access and mobility, which sets the technical details.
The Premises Standards and the NCC access provisions are aligned, so meeting the NCC Deemed-to-Satisfy provisions generally meets the Premises Standards for new building work.
Which buildings
Access requirements apply to most Class 3, 5, 6, 7, 8 and 9 buildings, to common areas of Class 2 apartment buildings in some cases, and to some Class 1b and Class 10 buildings and structures (such as public swimming pools and some carparks). The NCC sets which parts of each building must be accessible.
Houses (Class 1a) are not covered by these rules. New houses in most states have livable housing requirements instead.
What it covers
- Accessways: a continuous accessible path from the street, accessible parking and other buildings, through the principal entrance, and to the areas required to be accessible.
- Ramps, landings and step ramps, with set gradients and handrails.
- Doors: clear widths, circulation space, and hardware that can be used with one hand.
- Accessible toilets and showers, including unisex accessible facilities and, in some buildings, ambulant facilities.
- Lifts, where required.
- Tactile ground surface indicators at stairs, ramps and hazards.
- Signage, including braille and tactile signs for accessible facilities and exits.
- Hearing augmentation in some rooms.
Existing buildings
When new work is done to an existing building, the Premises Standards can require the affected part and the path from the entrance to it to be upgraded. There are concessions for existing lessees and limited exceptions, and unjustifiable hardship can be considered by the approval authority in some cases.
What it means for trades
- Builders and shopfitters: an alteration or fit-out can trigger access upgrades to the entrance and path of travel.
- Plumbers: accessible toilets and showers have set fixture heights, clearances and fittings.
- Electricians: switch and power outlet heights, and lighting levels in accessible areas.
What inspectors should look for
- A step at the principal entrance with no ramp or alternative accessible entrance
- Accessible toilets used as storage rooms
- Missing tactile indicators at stairs
- Door hardware that needs a tight grip or twist
Sources
- NCC 2022 Volume One, Part D4: ncc.abcb.gov.au
- Disability (Access to Premises — Buildings) Standards 2010: legislation.gov.au
This guide is general information, not legal or access consulting advice. AS 1428.1 is available from Standards Australia.