Building classes explained: Class 1 to Class 10

Every building in Australia has a class under the NCC, and the class decides which rules apply: which volume of the code, how fire-resistant it must be, how many exits it needs, and whether it needs disability access. Getting the class right is the first step for any job, and getting it wrong is behind a lot of non-compliant conversions.

Last checked: 13 November 2026. Based on NCC 2022 Part A6. A building can have more than one class. Check the edition and state variations that apply to your job.

Where the rules are

  • NCC Part A6, Building classification (in both Volume One and Volume Two).
  • Volume One covers Class 2 to 9 buildings (and disability access for some Class 1b and 10 buildings).
  • Volume Two and the Housing Provisions cover Class 1 and 10 buildings.
  • Volume Three (plumbing) applies to every class.

The classes

ClassWhat it isExamples
1aA single dwelling: a detached house, or one of a group of attached dwellingsHouse, townhouse, terrace, villa
1bA small boarding house, guest house or hostel, or a group of small holiday unitsB&B, small guest house
2A building with two or more separate dwellings (sole-occupancy units)Apartments, units, flats
3Other residential buildings for long-term or transient living by unrelated peopleHotel, motel, backpackers, boarding school dorm, shearers' quarters
4A single dwelling in a Class 5 to 9 buildingCaretaker's flat above a shop
5OfficeLawyers, accountants, most GP clinics
6Shop or sale of goods or services to the publicShop, restaurant, café, hairdresser
7aCarparkMulti-storey carpark
7bStorage or wholesaleWarehouse
8Laboratory, or a building for production, assembly, repair or processingFactory, workshop, lab
9aHealth-care buildingHospital, day surgery
9bAssembly buildingSchool, church, theatre, gym, kindergarten
9cResidential care buildingAged care
10aNon-habitable buildingGarage, carport, shed
10bStructureFence, retaining wall, pool, deck, mast
10cPrivate bushfire shelter

Some things to know

  • A Class 1 building can't be above or below another dwelling or another class, other than its own garage. Two dwellings stacked on top of each other, or over a shared basement, make Class 2.
  • A building can have more than one class, such as shops on the ground floor (Class 6) with apartments above (Class 2). Each part follows its own class's rules, with separation between them.
  • A minor use taking up a small part of a building can sometimes be treated as part of the main class. There are limits, such as for labs and childcare.
  • A medical practice where treatment leaves patients unconscious or unable to walk out becomes a health-care building (Class 9a), not an office.

Change of use

Changing how a building is used can change its class: a house to a boarding house, a shop to a café, a warehouse to a gym, a garage to a bedroom. A change of class usually needs approval and can trigger fire safety, access and other upgrades. See our garages and Class 10 guide.

What it means for trades

  • Fire and electrical trades: Class 2 to 9 buildings bring fire safety systems, emergency lighting and annual statements. See fire safety measures.
  • Building inspectors: a pre-purchase report on a "house" that is really two dwellings, or a converted garage, should say so.
  • Builders: the class sets the type of construction and the exit rules.

Sources

  • ABCB, "Understanding the NCC: Building classifications": nccb.gov.au
  • NCC Part A6: ncc.abcb.gov.au

This guide is general information, not legal or compliance advice.