Sound insulation between townhouses and attached houses

If you can hear the neighbour's TV, toilet or footsteps through the wall, the separating wall is not doing its job. The NCC sets minimum sound insulation for walls between attached houses (townhouses, terraces and duplexes) and, in Volume One, between apartments.

Last checked: 13 November 2026. Based on NCC 2022 Housing Provisions Part 10.7. The Northern Territory has its own variation. Check the edition and state variations that apply to your job.

Where the rules are

  • NCC Volume Two, Part H4, Health and amenity.
  • Housing Provisions Part 10.7, Sound insulation, for Class 1 buildings.
  • NCC Volume One, Part F7, for apartments (Class 2 and 3).

The rating

Sound insulation is measured as Rw + Ctr. Rw measures how well the wall blocks airborne sound like voices; Ctr is an adjustment for low-frequency noise like music, bass and traffic. The higher the number, the better.

Under the Housing Provisions, a separating wall between two houses, or between a house and a garage that belongs to the house next door, must have an Rw + Ctr of at least 50.

Where the wall separates a bathroom, toilet, laundry or kitchen in one house from a habitable room in the other, it must also resist impact sound (pipes, doors, things knocked against the wall), which usually means discontinuous construction: two separate leaves with no rigid connection between them.

The rating comes from laboratory test results for the wall system, or by building one of the wall types set out in the Housing Provisions.

Building it right

A wall system that tested well in a lab can still perform badly on site. The Housing Provisions set details that matter:

  • The wall must continue to the underside of the roof or the floor above, not stop at the ceiling.
  • Junctions with external walls and the roof must be sealed.
  • Services must not be chased into masonry or concrete separating walls.
  • Pipes and ducts in a separating wall need extra treatment, and power points shouldn't be back to back.

Apartments

For Class 2 and 3 buildings, Volume One sets Rw + Ctr 50 for walls and floors between units, plus impact sound limits for floors. See our building classes guide.

What inspectors should look for

  • Separating walls that stop at the ceiling, leaving the roof space open between houses
  • Gaps, penetrations and unsealed service holes in the separating wall
  • Plumbing on the separating wall, especially from bathrooms
  • Owner complaints of noise, which often point to a missing or broken detail

Sources

  • ABCB Housing Provisions Part 10.7: ncc.abcb.gov.au

This guide is general information, not legal or acoustic advice.