Stormwater is rain from roofs, paving and driveways. It has to go somewhere legal, and it must never end up in the sewer or soaking the ground under the house. Rainwater tanks capture some of it for use, but connected to the house they bring their own plumbing rules.

Last checked: 13 November 2026. Based on the NCC (Volume Two and Volume Three) and the way AS/NZS 3500.3 is called up. Councils set the legal point of discharge and often require on-site detention or tanks. Check yours.

Where the rules are

  • NCC Volume Two, Part H2, and Housing Provisions Parts 3.3 and 7.4 for site drainage, gutters and downpipes on houses. See our gutters guide and site drainage guide.
  • NCC Volume Three, the stormwater drainage provisions, and AS/NZS 3500.3 Stormwater drainage.
  • Volume Three water supply and cross-connection rules for rainwater tanks connected to the house.
  • Council stormwater policies: the legal point of discharge, on-site detention, and BASIX or similar requirements in some states.

Legal point of discharge

Stormwater must go to a legal point of discharge: usually the kerb and gutter, a council drainage pit or an inter-allotment easement, set by the council. Discharging onto a neighbour's land, into the sewer, or onto the ground next to the house is not allowed.

On sloping blocks that fall away from the street, this can mean an easement through a neighbour's property, a pump, or an absorption system approved by the council.

Stormwater in the sewer

Stormwater must not go into the sewer. In heavy rain it overloads the system and causes sewage overflows. Water utilities run programs to find illegal connections, such as downpipes connected to the sewer or an overflow relief gully set too low.

Pipes and pits

AS/NZS 3500.3 covers pipe sizes and grades, minimum cover over underground pipes (depending on whether they're under soil, paving or a driveway), pits and their grates, and how downpipes connect to the underground system.

Rainwater tanks

Tanks are common, and in some states required for new homes. Key points:

  • Overflow from the tank must go to the stormwater system, not onto the ground against the house.
  • Mosquito-proofing: screens on inlets and overflows.
  • First-flush devices divert the first, dirtiest water away from the tank.
  • Connection to the house (toilets, laundry, garden): where the house also has mains water, the tank system must be protected so tank water can never flow back into the public supply. That usually means a backflow prevention device or an automatic switching device with the right protection. See our backflow guide.
  • Pumps need power and are usually installed by an electrician; the plumbing work is licensed plumbing.
  • Signage: taps connected to tank water are labelled as rainwater.

What inspectors should look for

  • Downpipes discharging onto the ground next to the house, or into garden beds
  • Blocked, broken or root-filled stormwater pipes and pits
  • Ponding against the house after rain
  • Tank overflows discharging against the building
  • Tanks connected to the house with no visible backflow protection