Livable housing design: what new homes need

Since NCC 2022, new houses and apartments in most states must be built so they are easier to live in for people of all ages and abilities, and easier to adapt later. The requirements are modest (a step-free way in, wider doors, a step-free shower) but they change how slabs, bathrooms and entries are detailed.

Last checked: 13 November 2026. NSW and Western Australia have not adopted these rules, and other states adopted them on different dates. Check yours.

Where the rules are

  • NCC Volume Two, Part H8, Livable housing design (houses, Class 1a).
  • NCC Volume One, Part G7 (apartments, Class 2 sole-occupancy units).
  • The ABCB Livable Housing Design Standard, which sets the Deemed-to-Satisfy details. It is based on the Silver level of the earlier Livable Housing Design Guidelines.

Where it applies

  • Not adopted: NSW and Western Australia. The NSW variation states that Part H8 does not apply in NSW.
  • Adopted: the other states and territories, on their own dates from 2023, some with exemptions such as for small or steep lots. Check your state's variation.

The six requirements

In plain words, a new home must have:

  1. A step-free access path from the street or a parking space to the dwelling entrance.
  2. At least one step-free entrance door, with a clear opening of at least 820 mm and a level threshold. It doesn't have to be the front door.
  3. Wider internal doors and corridors on the entry level, so a wheelchair or walking frame can get through. Internal doors on that level need a clear opening of at least 820 mm.
  4. A toilet on the entry level (or ground floor), with space in front of the pan.
  5. A step-free shower, with no hob or step.
  6. Reinforced bathroom and toilet walls, so grab rails can be fitted later without opening up the wall.

The Livable Housing Design Standard sets the details: path widths and gradients, door clearances, the space around the toilet, shower falls and wall reinforcement locations.

What it changes on site

  • Slabs and set-downs: step-free entries and showers usually mean set-downs in the slab, planned before the pour.
  • Waterproofing: hobless showers need careful falls and waterproofing to keep water in the shower. See our wet area guide.
  • Framing: noggings or sheet reinforcement in bathroom and toilet walls.
  • Doors: 820 mm clear usually means a door leaf of around 870 mm or wider.

What inspectors should look for

On new homes in states that apply the rules:

  • A step at the designated entrance, or a threshold lip
  • Doors with less than 820 mm clear opening where they're required
  • A shower with a hob or step
  • No evidence of wall reinforcement in bathrooms (check the documentation)

Sources

  • ABCB, Livable Housing Design Standard and FAQ: nccb.gov.au
  • Master Builders Queensland, NCC livable housing documentation checklist
  • HIA, NCC 2022 state adoption summaries

This guide is general information, not legal or compliance advice.