Building in bushfire areas: AS 3959 and BAL ratings explained

Much of Australia's urban fringe is bushfire-prone land. If you are building, extending or renovating there, the NCC requires construction to resist bushfire attack, and the level of protection depends on the site's Bushfire Attack Level (BAL).

Last checked: 13 November 2026. This summarises the NCC and the BAL system; it does not reproduce AS 3959. Bushfire planning rules are set by each state. Check yours.

Where the rules are

  • NCC Volume Two, Part H7, Ancillary provisions and additional construction requirements, which covers construction in bushfire-prone areas.
  • AS 3959 Construction of buildings in bushfire-prone areas, or the NASH Standard for steel-framed construction in bushfire areas.
  • State planning rules decide which land is bushfire-prone (mapped "bushfire prone areas" or overlays) and sometimes add requirements of their own, such as NSW's Planning for Bush Fire Protection.

Bushfire Attack Levels

AS 3959 sets six BALs, based on how much radiant heat and ember attack a building could face:

BALWhat it means
BAL-LOWRisk too low to need specific construction requirements
BAL-12.5Mainly ember attack; radiant heat up to 12.5 kW/m²
BAL-19More ember attack and burning debris; radiant heat 12.5 to 19 kW/m²
BAL-29Higher ember attack; radiant heat 19 to 29 kW/m²
BAL-40Very high risk; radiant heat 29 to 40 kW/m², some flame contact possible
BAL-FZFlame zone: direct flame contact, radiant heat above 40 kW/m²

The BAL is assessed from the fire danger index for the area, the type of vegetation, the distance from the vegetation, and the slope of the land under it. Some states require a minimum of BAL-12.5 in designated bushfire-prone areas even if the assessment comes back BAL-LOW.

What the BAL changes

Each level adds requirements, mainly about stopping embers getting in and stopping the building catching fire from radiant heat:

  • Sealing gaps around doors, windows, roof and eaves, and screening vents and weep holes with ember guards.
  • Windows and glazing: toughened glass, screens or shutters at higher levels.
  • External walls and cladding: non-combustible or tested materials at higher levels.
  • Roofs, gutters and valleys: sarking, sealed roofs, and gutter guards at some levels.
  • Decks, stairs and balustrades: non-combustible or bushfire-resistant timber.
  • Subfloors: enclosed or protected so embers cannot collect under the house.
  • Water and gas pipes above ground: metal at higher levels.

BAL-FZ construction is specialised and usually needs tested systems.

Renovations and maintenance

Extensions on bushfire-prone land generally need to meet the BAL for the site. Owners also need to keep the protection working: clean gutters, keep vents and screens intact, and manage vegetation near the house.

What inspectors should look for

  • Gaps where embers can enter: unsealed eaves, missing weep hole screens, gaps under doors
  • Leaves in gutters and valleys
  • Combustible material stored against the house or under timber decks
  • Damaged ember screens and vent covers