Roof cladding, roof tiles and sarking under the NCC
A roof has one job: keep the weather out for decades. The NCC's Deemed-to-Satisfy rules for metal and tiled roofs cover pitch, fixing, corrosion and sarking, and most roof leaks trace back to one of those.
Last checked: 13 November 2026. Based on NCC 2022 Housing Provisions Parts 7.2 and 7.3. Check the edition, state variations and the manufacturer's instructions for your job.
Where the rules are
- NCC Volume Two, Part H1 (structure) and Part H2 (weatherproofing).
- Housing Provisions Part 7.2, Sheet roofing.
- Housing Provisions Part 7.3, Roof tiles and shingles.
These Deemed-to-Satisfy parts have limits, such as the wind classification of the site. Outside those limits, the roof needs to follow the relevant Australian Standard or the manufacturer's tested system.
Metal sheet roofing (Part 7.2)
- Minimum pitch depends on the profile. Deeper trapezoidal profiles can go flatter than corrugated. The Housing Provisions give the minimums in a figure, and the manufacturer's literature does too.
- Spans between battens or purlins are limited by profile and sheet thickness.
- Fixing follows the profile and wind class, through the crest or the pan as specified.
- Corrosion protection depends on the environment (coast, industry) and on what the sheet touches. Some metals must not be in contact with each other or receive water run-off from each other, such as copper or lead run-off onto zinc-coated steel.
- Thermal expansion: very long pierce-fixed sheets need expansion joints.
Roof tiles (Part 7.3)
- Tiles and their hip, ridge and barge tiles must be fixed mechanically as set out in the Housing Provisions, which depends on the wind class.
- Tiles must comply with AS 2049.
- Sarking (the membrane under the tiles) is required where the rafter or truss top chord is longer than a set length for the roof pitch. The steeper the roof, the longer the run allowed without sarking. Very low-pitched tiled roofs fall outside the simple table, so check the Housing Provisions and the tile manufacturer.
- Where sarking is installed, it must be lapped or taped, fixed at close centres, and not sag too much. An anti-ponding board is needed at the eaves in some situations, so water on the sarking can reach the gutter.
- Lead flashings must not be used on roofs that are part of a drinking water catchment.
Sarking as insulation
Where sarking is also reflective insulation for energy efficiency, Section 13 of the Housing Provisions sets the R-values and air spaces. See our energy efficiency guide.
What inspectors should look for
- Cracked, slipped or missing tiles, and loose ridge capping or perished pointing
- Rusted sheets, fixings or flashings, especially where different metals meet
- Water stains on sarking, timbers or ceilings
- Roof pitch that looks too flat for the profile
- Missing sarking or sagging sarking holding water
Sources
- ABCB Housing Provisions Parts 7.2 and 7.3: ncc.abcb.gov.au
This guide is general information, not legal or compliance advice.